3-Jaw Microvascular Clamp with Approximator
3-Jaw Microvascular Clamp with Approximator
3-Jaw Microvascular Clamp with Approximator
Patented. Peer-reviewed. Trusted across 500+ surgeries.
The Shira 3-Jaw Clamp is the only microvascular approximator clamp in the world with three jaws, protected by Shira's patent. It is the result of translational research at IIT Madras, validated in three peer-reviewed publications including a randomised controlled trial, and used at leading microsurgery centres including AIIMS, Apollo, Fortis, Max, Medanta and Aster.
What surgeons experience with conventional 2-jaw clamps
- Vessel wall folds inward (backwalling), obscuring the lumen
- Clamp must be flipped to suture the posterior wall — adding time and risk
- Adventectomy required to prevent tissue entrapment
- OT light reflection off the clamp reduces visibility
- Vessel slippage from clamp jaws
How the 3-Jaw mechanism solves each problem
| Problem | 3-Jaw Solution | Surgical Benefit |
|---|---|---|
| Backwalling / lumen obscured | The third jaw holds the adventitia and everts the vessel wall, keeping the lumen open | 0% backwalling — confirmed in published results (vs 30.8% with Acland® clamps, PRS 2022) |
| Posterior wall suturing requires clamp flip | Everted lumen gives direct posterior wall access | Clamp flip eliminated — no position change needed (RCT, JPRAS 2023) |
| Adventectomy needed | Third jaw grips the adventitia instead of trimming it | Minimal adventectomy — adventitia is used to evert the vessel |
| Anastomosis time | Faster set-up, no flip, minimal adventectomy | 2× faster — about 50% less suturing time in both veins and arteries (RCT, JPRAS 2023) |
| OT light reflection | Black anti-reflective coating on all jaw surfaces | Zero glare — easy to identify the clamp under the microscope |
| Vessel slippage | Micro-grit gripping surface on jaw faces | Secure grip at calibrated closing pressure |
Clinical validation
- Randomised controlled trial (30 patients, 60 anastomoses): suturing time roughly halved — artery 15.9 vs 29.8 min, vein 16.6 vs 33.4 min vs Acland® clamps (p<0.001); no clamp flipping; assistant needed in 2 of 15 vs 14 of 15 cases; flap survival 93.3% in both groups. Journal of Plastic, Reconstructive & Aesthetic Surgery, 2023.
- Trainee study (25 anastomoses): 0% backwalling vs 30.8% with Acland® clamps; 0% clamp flips vs 38.5%; anastomosis time 20.8 vs 32.3 min (p=0.007). Plastic and Reconstructive Surgery, 2022.
- Technique report: first clinical description of the 3-jaw eversion technique. Journal of Plastic, Reconstructive & Aesthetic Surgery, 2022.
- Dr. Aniket Dave (Ahmedabad): 500+ surgeries using the Shira 3-Jaw Clamp
Engineering specifications
- Calibrated closing pressure — sufficient and consistent grip without over-compression
- Black anti-reflective coating on all jaw surfaces
- Micro-grit gripping surface to prevent vessel slippage
- Fits Shira Clamp Sterilization Case (7-clamp capacity)
- Compatible with Shira Clamp Applicator (asymmetric jaw design required for 2VV/2AA sizes)
Clamp sizes
| Size | Vessel diameter | Calibrated closing pressure |
|---|---|---|
| 1A / 1V | 0.4–1.0 mm | 18–21 g |
| 2AA / 2VV | 0.6–1.5 mm | 29–32 g |
| 3AA / 3VV | 1.0–2.25 mm | 42–45 g |
| HDD | 1.5–3.5 mm | 76–80 g |
| RDD | 3–4 mm | 135–145 g |
A = artery, V = vein.
If there is no adventitia
The 3-Jaw Clamp can be used exactly like a 2-jaw clamp when the vessel has minimal adventitia — no technique change required.
ISO 13485 Certified · CDSCO Registered · MDA Malaysia Registered · Exported to 20+ countries
Read the peer-reviewed clinical evidence | 3-Jaw vs Acland® comparison | Request a Quote or Sample Evaluation
Acland® is a registered trademark of S&T AG. Shira Medtech is not affiliated with S&T AG.
Share

Institutional & Distributor Enquiries
MOQ 1 unit · Ships worldwide · anand@shiramedtech.com
Institutional & Distributor Enquiries
MOQ 1 unit · Ships worldwide · anand@shiramedtech.com
- ISO 13485:2016
- CDSCO Registered
- MDA Malaysia Approved
- IIT Madras Technology
- 20+ Countries
- 3 Peer-Reviewed Publications